         Phone
Phone

◆ Suitable for resistive and inductive loads
◆ CE certification
| 1 | Load Control Element | hyristor (SCR) Module | 
| 2 | Load Power Supply | Single-phase 220V AC  Three-phase 380V AC ±10% 50HZ | 
| 3 | Control Input | 4~20mA   input, receiving impedance 120Ω | 
| 4 | Output Resolution | Phase Control: 0.6°; Power Control: 20ms | 
| 5 | Phase Shift Range | 0~175° | 
| 6 | Drive Output | 1). Output: 12V pulse, variable pulse width, maximum drive current: < 30mA. Compatible with P-type SSR, integrating voltage regulation/power control functions. 2). Pulse transformer output: slotted pulse, compatible with MKK/MTC anti-parallel modules, enabling single-phase voltage regulation and full-control rectification, but without power control mode. | 
| 7 | LED Status Indicator | Green: INPUT signal linear indicator light. Tricolor status lights: RUN green operation light; ALM red alarm light; STOP yellow flashing standby light。 | 
| 8 | Soft Start and Soft Shutdown RS for External Actuator Switch 
 | 
					No Voltage Contact Input 
 | 
| 9 | Automatic soft start and emergency stop during operation 
 | Emergency stop due to overcurrent or overtemperature during operation, with the protection response time for overcurrent and overtemperature not exceeding one power cycle (20ms). | 
| 10 | 70℃ Overtemperature Protection | 
					Voltage-free Normally Closed Contact | 
| 11 | Alarm Relay | One set of normally open contacts (pure resistance 1A 250VAC). | 
| 12 | Alarm Type | Overcurrent, Heatsink Overtemperature. | 
| 13 | CT Maximum Current Limit | 
					External 10K potentiometer, adjustment range 20% to 100%. | 
| 14 | Overcurrent Protection | 
					Adjusted by internal potentiometer P2. Reference point 1V; |